Based on kernel version 6.9. Page generated on 2024-05-14 10:02 EST.
| 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 |
TI ADC128D818 ADC System Monitor With Temperature Sensor
--------------------------------------------------------
Operation modes:
- Mode 0: 7 single-ended voltage readings (IN0-IN6),
1 temperature reading (internal)
- Mode 1: 8 single-ended voltage readings (IN0-IN7),
no temperature
- Mode 2: 4 pseudo-differential voltage readings
(IN0-IN1, IN3-IN2, IN4-IN5, IN7-IN6),
1 temperature reading (internal)
- Mode 3: 4 single-ended voltage readings (IN0-IN3),
2 pseudo-differential voltage readings
(IN4-IN5, IN7-IN6),
1 temperature reading (internal)
If no operation mode is configured via device tree, the driver keeps the
currently active chip operation mode (default is mode 0).
Required node properties:
- compatible: must be set to "ti,adc128d818"
- reg: I2C address of the device
Optional node properties:
- ti,mode: Operation mode (u8) (see above).
Example (operation mode 2):
adc128d818@1d {
compatible = "ti,adc128d818";
reg = <0x1d>;
ti,mode = /bits/ 8 <2>;
};
|