1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404
=======================
Energy Aware Scheduling
=======================

1. Introduction
---------------

Energy Aware Scheduling (or EAS) gives the scheduler the ability to predict
the impact of its decisions on the energy consumed by CPUs. EAS relies on an
Energy Model (EM) of the CPUs to select an energy efficient CPU for each task,
with a minimal impact on throughput. This document aims at providing an
introduction on how EAS works, what are the main design decisions behind it, and
details what is needed to get it to run.

Before going any further, please note that at the time of writing::

   /!\ EAS does not support platforms with symmetric CPU topologies /!\

EAS operates only on heterogeneous CPU topologies (such as Arm big.LITTLE)
because this is where the potential for saving energy through scheduling is
the highest.

The actual EM used by EAS is _not_ maintained by the scheduler, but by a
dedicated framework. For details about this framework and what it provides,
please refer to its documentation (see Documentation/power/energy-model.rst).


2. Background and Terminology
-----------------------------

To make it clear from the start:
 - energy = [joule] (resource like a battery on powered devices)
 - power = energy/time = [joule/second] = [watt]

The goal of EAS is to minimize energy, while still getting the job done. That
is, we want to maximize::

	performance [inst/s]
	--------------------
	    power [W]

which is equivalent to minimizing::

	energy [J]
	-----------
	instruction

while still getting 'good' performance. It is essentially an alternative
optimization objective to the current performance-only objective for the
scheduler. This alternative considers two objectives: energy-efficiency and
performance.

The idea behind introducing an EM is to allow the scheduler to evaluate the
implications of its decisions rather than blindly applying energy-saving
techniques that may have positive effects only on some platforms. At the same
time, the EM must be as simple as possible to minimize the scheduler latency
impact.

In short, EAS changes the way CFS tasks are assigned to CPUs. When it is time
for the scheduler to decide where a task should run (during wake-up), the EM
is used to break the tie between several good CPU candidates and pick the one
that is predicted to yield the best energy consumption without harming the
system's throughput. The predictions made by EAS rely on specific elements of
knowledge about the platform's topology, which include the 'capacity' of CPUs,
and their respective energy costs.


3. Topology information
-----------------------

EAS (as well as the rest of the scheduler) uses the notion of 'capacity' to
differentiate CPUs with different computing throughput. The 'capacity' of a CPU
represents the amount of work it can absorb when running at its highest
frequency compared to the most capable CPU of the system. Capacity values are
normalized in a 1024 range, and are comparable with the utilization signals of
tasks and CPUs computed by the Per-Entity Load Tracking (PELT) mechanism. Thanks
to capacity and utilization values, EAS is able to estimate how big/busy a
task/CPU is, and to take this into consideration when evaluating performance vs
energy trade-offs. The capacity of CPUs is provided via arch-specific code
through the arch_scale_cpu_capacity() callback.

The rest of platform knowledge used by EAS is directly read from the Energy
Model (EM) framework. The EM of a platform is composed of a power cost table
per 'performance domain' in the system (see Documentation/power/energy-model.rst
for further details about performance domains).

The scheduler manages references to the EM objects in the topology code when the
scheduling domains are built, or re-built. For each root domain (rd), the
scheduler maintains a singly linked list of all performance domains intersecting
the current rd->span. Each node in the list contains a pointer to a struct
em_perf_domain as provided by the EM framework.

The lists are attached to the root domains in order to cope with exclusive
cpuset configurations. Since the boundaries of exclusive cpusets do not
necessarily match those of performance domains, the lists of different root
domains can contain duplicate elements.

Example 1.
    Let us consider a platform with 12 CPUs, split in 3 performance domains
    (pd0, pd4 and pd8), organized as follows::

	          CPUs:   0 1 2 3 4 5 6 7 8 9 10 11
	          PDs:   |--pd0--|--pd4--|---pd8---|
	          RDs:   |----rd1----|-----rd2-----|

    Now, consider that userspace decided to split the system with two
    exclusive cpusets, hence creating two independent root domains, each
    containing 6 CPUs. The two root domains are denoted rd1 and rd2 in the
    above figure. Since pd4 intersects with both rd1 and rd2, it will be
    present in the linked list '->pd' attached to each of them:

       * rd1->pd: pd0 -> pd4
       * rd2->pd: pd4 -> pd8

    Please note that the scheduler will create two duplicate list nodes for
    pd4 (one for each list). However, both just hold a pointer to the same
    shared data structure of the EM framework.

Since the access to these lists can happen concurrently with hotplug and other
things, they are protected by RCU, like the rest of topology structures
manipulated by the scheduler.

EAS also maintains a static key (sched_energy_present) which is enabled when at
least one root domain meets all conditions for EAS to start. Those conditions
are summarized in Section 6.


4. Energy-Aware task placement
------------------------------

EAS overrides the CFS task wake-up balancing code. It uses the EM of the
platform and the PELT signals to choose an energy-efficient target CPU during
wake-up balance. When EAS is enabled, select_task_rq_fair() calls
find_energy_efficient_cpu() to do the placement decision. This function looks
for the CPU with the highest spare capacity (CPU capacity - CPU utilization) in
each performance domain since it is the one which will allow us to keep the
frequency the lowest. Then, the function checks if placing the task there could
save energy compared to leaving it on prev_cpu, i.e. the CPU where the task ran
in its previous activation.

find_energy_efficient_cpu() uses compute_energy() to estimate what will be the
energy consumed by the system if the waking task was migrated. compute_energy()
looks at the current utilization landscape of the CPUs and adjusts it to
'simulate' the task migration. The EM framework provides the em_pd_energy() API
which computes the expected energy consumption of each performance domain for
the given utilization landscape.

An example of energy-optimized task placement decision is detailed below.

Example 2.
    Let us consider a (fake) platform with 2 independent performance domains
    composed of two CPUs each. CPU0 and CPU1 are little CPUs; CPU2 and CPU3
    are big.

    The scheduler must decide where to place a task P whose util_avg = 200
    and prev_cpu = 0.

    The current utilization landscape of the CPUs is depicted on the graph
    below. CPUs 0-3 have a util_avg of 400, 100, 600 and 500 respectively
    Each performance domain has three Operating Performance Points (OPPs).
    The CPU capacity and power cost associated with each OPP is listed in
    the Energy Model table. The util_avg of P is shown on the figures
    below as 'PP'::

     CPU util.
      1024                 - - - - - - -              Energy Model
                                               +-----------+-------------+
                                               |  Little   |     Big     |
       768                 =============       +-----+-----+------+------+
                                               | Cap | Pwr | Cap  | Pwr  |
                                               +-----+-----+------+------+
       512  ===========    - ##- - - - -       | 170 | 50  | 512  | 400  |
                             ##     ##         | 341 | 150 | 768  | 800  |
       341  -PP - - - -      ##     ##         | 512 | 300 | 1024 | 1700 |
             PP              ##     ##         +-----+-----+------+------+
       170  -## - - - -      ##     ##
             ##     ##       ##     ##
           ------------    -------------
            CPU0   CPU1     CPU2   CPU3

      Current OPP: =====       Other OPP: - - -     util_avg (100 each): ##


    find_energy_efficient_cpu() will first look for the CPUs with the
    maximum spare capacity in the two performance domains. In this example,
    CPU1 and CPU3. Then it will estimate the energy of the system if P was
    placed on either of them, and check if that would save some energy
    compared to leaving P on CPU0. EAS assumes that OPPs follow utilization
    (which is coherent with the behaviour of the schedutil CPUFreq
    governor, see Section 6. for more details on this topic).

    **Case 1. P is migrated to CPU1**::

      1024                 - - - - - - -

                                            Energy calculation:
       768                 =============     * CPU0: 200 / 341 * 150 = 88
                                             * CPU1: 300 / 341 * 150 = 131
                                             * CPU2: 600 / 768 * 800 = 625
       512  - - - - - -    - ##- - - - -     * CPU3: 500 / 768 * 800 = 520
                             ##     ##          => total_energy = 1364
       341  ===========      ##     ##
                    PP       ##     ##
       170  -## - - PP-      ##     ##
             ##     ##       ##     ##
           ------------    -------------
            CPU0   CPU1     CPU2   CPU3


    **Case 2. P is migrated to CPU3**::

      1024                 - - - - - - -

                                            Energy calculation:
       768                 =============     * CPU0: 200 / 341 * 150 = 88
                                             * CPU1: 100 / 341 * 150 = 43
                                    PP       * CPU2: 600 / 768 * 800 = 625
       512  - - - - - -    - ##- - -PP -     * CPU3: 700 / 768 * 800 = 729
                             ##     ##          => total_energy = 1485
       341  ===========      ##     ##
                             ##     ##
       170  -## - - - -      ##     ##
             ##     ##       ##     ##
           ------------    -------------
            CPU0   CPU1     CPU2   CPU3


    **Case 3. P stays on prev_cpu / CPU 0**::

      1024                 - - - - - - -

                                            Energy calculation:
       768                 =============     * CPU0: 400 / 512 * 300 = 234
                                             * CPU1: 100 / 512 * 300 = 58
                                             * CPU2: 600 / 768 * 800 = 625
       512  ===========    - ##- - - - -     * CPU3: 500 / 768 * 800 = 520
                             ##     ##          => total_energy = 1437
       341  -PP - - - -      ##     ##
             PP              ##     ##
       170  -## - - - -      ##     ##
             ##     ##       ##     ##
           ------------    -------------
            CPU0   CPU1     CPU2   CPU3


    From these calculations, the Case 1 has the lowest total energy. So CPU 1
    is be the best candidate from an energy-efficiency standpoint.

Big CPUs are generally more power hungry than the little ones and are thus used
mainly when a task doesn't fit the littles. However, little CPUs aren't always
necessarily more energy-efficient than big CPUs. For some systems, the high OPPs
of the little CPUs can be less energy-efficient than the lowest OPPs of the
bigs, for example. So, if the little CPUs happen to have enough utilization at
a specific point in time, a small task waking up at that moment could be better
of executing on the big side in order to save energy, even though it would fit
on the little side.

And even in the case where all OPPs of the big CPUs are less energy-efficient
than those of the little, using the big CPUs for a small task might still, under
specific conditions, save energy. Indeed, placing a task on a little CPU can
result in raising the OPP of the entire performance domain, and that will
increase the cost of the tasks already running there. If the waking task is
placed on a big CPU, its own execution cost might be higher than if it was
running on a little, but it won't impact the other tasks of the little CPUs
which will keep running at a lower OPP. So, when considering the total energy
consumed by CPUs, the extra cost of running that one task on a big core can be
smaller than the cost of raising the OPP on the little CPUs for all the other
tasks.

The examples above would be nearly impossible to get right in a generic way, and
for all platforms, without knowing the cost of running at different OPPs on all
CPUs of the system. Thanks to its EM-based design, EAS should cope with them
correctly without too many troubles. However, in order to ensure a minimal
impact on throughput for high-utilization scenarios, EAS also implements another
mechanism called 'over-utilization'.


5. Over-utilization
-------------------

From a general standpoint, the use-cases where EAS can help the most are those
involving a light/medium CPU utilization. Whenever long CPU-bound tasks are
being run, they will require all of the available CPU capacity, and there isn't
much that can be done by the scheduler to save energy without severely harming
throughput. In order to avoid hurting performance with EAS, CPUs are flagged as
'over-utilized' as soon as they are used at more than 80% of their compute
capacity. As long as no CPUs are over-utilized in a root domain, load balancing
is disabled and EAS overridess the wake-up balancing code. EAS is likely to load
the most energy efficient CPUs of the system more than the others if that can be
done without harming throughput. So, the load-balancer is disabled to prevent
it from breaking the energy-efficient task placement found by EAS. It is safe to
do so when the system isn't overutilized since being below the 80% tipping point
implies that:

    a. there is some idle time on all CPUs, so the utilization signals used by
       EAS are likely to accurately represent the 'size' of the various tasks
       in the system;
    b. all tasks should already be provided with enough CPU capacity,
       regardless of their nice values;
    c. since there is spare capacity all tasks must be blocking/sleeping
       regularly and balancing at wake-up is sufficient.

As soon as one CPU goes above the 80% tipping point, at least one of the three
assumptions above becomes incorrect. In this scenario, the 'overutilized' flag
is raised for the entire root domain, EAS is disabled, and the load-balancer is
re-enabled. By doing so, the scheduler falls back onto load-based algorithms for
wake-up and load balance under CPU-bound conditions. This provides a better
respect of the nice values of tasks.

Since the notion of overutilization largely relies on detecting whether or not
there is some idle time in the system, the CPU capacity 'stolen' by higher
(than CFS) scheduling classes (as well as IRQ) must be taken into account. As
such, the detection of overutilization accounts for the capacity used not only
by CFS tasks, but also by the other scheduling classes and IRQ.


6. Dependencies and requirements for EAS
----------------------------------------

Energy Aware Scheduling depends on the CPUs of the system having specific
hardware properties and on other features of the kernel being enabled. This
section lists these dependencies and provides hints as to how they can be met.


6.1 - Asymmetric CPU topology
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^


As mentioned in the introduction, EAS is only supported on platforms with
asymmetric CPU topologies for now. This requirement is checked at run-time by
looking for the presence of the SD_ASYM_CPUCAPACITY_FULL flag when the scheduling
domains are built.

See Documentation/scheduler/sched-capacity.rst for requirements to be met for this
flag to be set in the sched_domain hierarchy.

Please note that EAS is not fundamentally incompatible with SMP, but no
significant savings on SMP platforms have been observed yet. This restriction
could be amended in the future if proven otherwise.


6.2 - Energy Model presence
^^^^^^^^^^^^^^^^^^^^^^^^^^^

EAS uses the EM of a platform to estimate the impact of scheduling decisions on
energy. So, your platform must provide power cost tables to the EM framework in
order to make EAS start. To do so, please refer to documentation of the
independent EM framework in Documentation/power/energy-model.rst.

Please also note that the scheduling domains need to be re-built after the
EM has been registered in order to start EAS.

EAS uses the EM to make a forecasting decision on energy usage and thus it is
more focused on the difference when checking possible options for task
placement. For EAS it doesn't matter whether the EM power values are expressed
in milli-Watts or in an 'abstract scale'.


6.3 - Energy Model complexity
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^

EAS does not impose any complexity limit on the number of PDs/OPPs/CPUs but
restricts the number of CPUs to EM_MAX_NUM_CPUS to prevent overflows during
the energy estimation.


6.4 - Schedutil governor
^^^^^^^^^^^^^^^^^^^^^^^^

EAS tries to predict at which OPP will the CPUs be running in the close future
in order to estimate their energy consumption. To do so, it is assumed that OPPs
of CPUs follow their utilization.

Although it is very difficult to provide hard guarantees regarding the accuracy
of this assumption in practice (because the hardware might not do what it is
told to do, for example), schedutil as opposed to other CPUFreq governors at
least _requests_ frequencies calculated using the utilization signals.
Consequently, the only sane governor to use together with EAS is schedutil,
because it is the only one providing some degree of consistency between
frequency requests and energy predictions.

Using EAS with any other governor than schedutil is not supported.


6.5 Scale-invariant utilization signals
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^

In order to make accurate prediction across CPUs and for all performance
states, EAS needs frequency-invariant and CPU-invariant PELT signals. These can
be obtained using the architecture-defined arch_scale{cpu,freq}_capacity()
callbacks.

Using EAS on a platform that doesn't implement these two callbacks is not
supported.


6.6 Multithreading (SMT)
^^^^^^^^^^^^^^^^^^^^^^^^

EAS in its current form is SMT unaware and is not able to leverage
multithreaded hardware to save energy. EAS considers threads as independent
CPUs, which can actually be counter-productive for both performance and energy.

EAS on SMT is not supported.